Description: Site-wide storm water systems handling peak monsoon flows via catch pits, gratings, roadside drains, and underground pipes to outfalls/recharge structures. We design gradients and capacities to prevent flooding, waterlogging, and damage to roads, basements, or landscaping.
Compliances: Local municipal storm-water norms; NBC/CPHEEO guidance for drainage design.
Benefits: Flood-safe site, longer pavement life, clean landscaped areas, reduced complaints and downtime.
Why Choose Us: Accurate hydraulic calculations, proper silt control, accessible chambers, and as-built levels that actually match site contours.
Description: Capture and utilize roof/terrace runoff through down-take pipes, filters, silt traps, storage, and recharge pits/bores or reuse loops. We size components based on rainfall intensity and roof area so your system actually works during monsoons and reduces dependency on tankers/municipal supply.
Compliances: Local development authority RWH by-laws; NBC guidance on water conservation; CPHEEO practices.
Benefits: Lower freshwater bills, improved groundwater recharge, ESG/green points, reduced storm drain burden.
Why Choose Us: Correct hydraulic sizing, debris/silt control, safe overflow paths, and easy-to-maintain filter layouts with documented O&M.
Description: End-to-end design and execution of building/industrial water networks—from source tapping and treatment interface to storage, boosting, and floor-wise distribution. We engineer pipes, valves, NRVs, PRVs and meters so every outlet gets the right pressure/flow without noise, hammer, or dead legs. Suitable for residential towers, IT parks, malls, hospitals, and plants.
Compliances: NBC 2016 guidance for plumbing; CPHEEO Manual practices; IS pipe/material standards as specified by client/authority.
Benefits: Assured pressure at fixtures, reduced leakage and water hammer, hygienic layouts, simplified maintenance, and lower lifecycle costs.
Why Choose Us: Practical hydraulics, accurate sizing, clean riser/shaft detailing, and commissioning with pressure/flow records—plus clear as-builts and O&M for facility teams.
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description:
Early detection of water leaks in data centers, server rooms, UPS rooms, laboratories, archives and false floors using spot sensors or addressable leak‑detection cables. The system pinpoints location, triggers local/buzzer alarms, and can notify BMS to shut down sensitive equipment or close motorized valves.
Compliances:
Best practices for mission‑critical facilities; OEM sensor/controller guidelines; integration per BMS protocols.
Benefits:
Prevents damage to electrical/electronics, reduces downtime, and protects high‑value rooms and records.
Why Choose Us:
Clean cable routing, address mapping, supervised loops, and tested alarms with clear as‑builts and maintenance SOPs.
Description:
Process cooling networks designed for flow balance, NPSH, and temperature control—covering cooling towers, pumps, exchangers, and distribution. We minimize pumping power, ensure correct velocities, and plan chemical treatment points.
Compliances:
IS/ASHRAE guidance for cooling water; OEM guidelines for exchangers/pumps; water chemistry best practices.
Benefits:
Lower energy per m³, stable process temperatures, reduced fouling/scaling, and longer equipment life.
Why Choose Us:
Hydraulic modeling, debris management, treatment dosing, and well-documented O&M with KPIs for ΔT, approach, and cycles of concentration.
Description: Engineered sumps, lift stations, and pump rooms for water, flushing, storm and sewage transfer. We size pumps, NPSH, suction headers, and controls (float/pressure/BMS) so starts/stops are smooth, cavitation is avoided, and standby logic is fail-safe. Delivered with valves, NRVs, strainers, level instrumentation, and safety features.
Compliances: NBC plumbing guidance; IS practices for pumps/valves/electrical; local electrical approvals as applicable.
Benefits: Reliable transfer without dry-run or overflow, lower energy usage with correct duty points, easy service access and documented logic.
Why Choose Us: We combine hydraulics with controls—proper cable trays, ventilation, sump access, and clear SOPs—so facilities can run the system worry-free.
Description: WTPs convert raw surface or bore water into reliable potable or process water by removing turbidity, microbes, color, and dissolved contaminants. Based on source quality, we deploy conventional clarification, pressure filters, and UF/RO combinations to produce water that is safe, pleasant, and consistent year-round, even through monsoons and seasonal changes. Plants are modular, scalable, and designed for low downtime and easy O&M.
Compliances: IS 10500 for potable water (as applicable), WHO guidance (reference), and client-specified process limits.
Benefits: Stable quality for drinking and process, lower scaling/fouling downstream, manageable chemical use, and operator-friendly automation.
Why Choose Us: Holistic design with raw-to-tap engineering, interconnecting piping/cabling, dosing skids, trial run & handover packs, and on-site training to ensure smooth takeover.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar