Description:
End‑to‑end LV/MV distribution—transformers, panels, feeders, and protective devices—laid out for reliability, selectivity, and maintainability. We balance loading, plan redundancy, and label everything so operations teams can work safely and efficiently.
Compliances:
IS/IEC wiring & protection; utility metering norms; safety per IE Rules.
Benefits:
Reduced downtime, easier isolation, measurable energy flows, and readiness for expansions.
Why Choose Us:
Strong documentation (SLD, feeder schedules), disciplined execution, and commissioning with pre/post test sheets.
Description:
Outdoor and industrial lighting engineered for lux uniformity, safety, and energy efficiency. We perform lighting layout, pole selection, optics, and controls—covering streets, yards, factories, and warehouses.
Compliances:
IS lighting practices; local electrical codes; recommended lux levels per application.
Benefits:
Better visibility & safety, lower energy bills, reduced maintenance with long‑life luminaires.
Why Choose Us:
Lighting calculations, correct optics, surge‑protected drivers, and scalable control options from simple timers to IoT.
Description: End-to-end design and execution of building/industrial water networks—from source tapping and treatment interface to storage, boosting, and floor-wise distribution. We engineer pipes, valves, NRVs, PRVs and meters so every outlet gets the right pressure/flow without noise, hammer, or dead legs. Suitable for residential towers, IT parks, malls, hospitals, and plants.
Compliances: NBC 2016 guidance for plumbing; CPHEEO Manual practices; IS pipe/material standards as specified by client/authority.
Benefits: Assured pressure at fixtures, reduced leakage and water hammer, hygienic layouts, simplified maintenance, and lower lifecycle costs.
Why Choose Us: Practical hydraulics, accurate sizing, clean riser/shaft detailing, and commissioning with pressure/flow records—plus clear as-builts and O&M for facility teams.
Description:
Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor.
Compliances:
- NBC 2016 – Part 4 (Fire & Life Safety)
- IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets
- IS 2189 / NFPA 72 for fire detection & alarm (when in scope)
- NFPA 20 / NFPA 13 / NFPA 2001 (as applicable)
- Local CFO / Fire Brigade requirements for provisional and final NOC
Benefits:
- One-point accountability – no multi-vendor disputes
- Faster fire NOC because drawings, test certificates and demonstrations are handled together
- Standardised and approved make materials → better reliability
- Installation with testing (hydro, flushing, pump trials) and complete O&M handover
- Option to continue with AMC from the same team
Why Choose Us:
- Govt-approved / class-A fire & safety contractor with multi-sector experience
- Fire projects executed in industrial, healthcare, warehousing and commercial facilities
- We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority
- We train your operators on hydrant/sprinkler/pump panel so the system is actually usable
- Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Description:
Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses.
Key Components:
Sprinkler heads (pendent, upright, sidewall)
Distribution piping & alarm valves
Water supply pumps & tanks
Flow switches & monitoring systems
Compliance:
IS 15105 – Design & installation requirements for sprinkler systems
NFPA 13 – Standard for installation of sprinkler systems
NBC 2016 – Fire zone & occupancy-specific guidelines
Why Choose Us:
We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform.
Benefits:
Quick suppression at fire origin
Reduces smoke & property damage
Automatic activation without human intervention
Description:
End‑to‑end ducting with correct gauges, leakage class, insulation and acoustics. We design for low-pressure drops, proper diffuser selection, throw and noise criteria to keep spaces comfortable and quiet.
Compliances:
SMACNA/IS duct standards; NBC/ASHRAE comfort and noise guidance.
Benefits:
Lower fan power, uniform temperatures, reduced noise/condensation, and clean finishes.
Why Choose Us:
Detail‑oriented shop drawings, hangers/supports, airtight joints, and site QA with leakage checks.
Description:
Design and build of process control panels integrating PLCs, MCCs, and VFDs with field instruments and drives. We deliver clean wiring, labeling, interlocks, and tested logic so operations can trust the pushbuttons and screens.
Compliances:
IS/IEC for panels and wiring; ISA practices for control & alarm philosophy; safety interlocks per process needs.
Benefits:
Reliable control, reduced downtime, clearer diagnostics, and easier expansion.
Why Choose Us:
Panel GA & wiring drawings, IO lists, cause‑&‑effect, FAT/SAT, and comprehensive O&M/training packs.
Still searching for indoor outdoor ht distribution panels?