Pune
08042755939
+918956051383

'energy efficient compressed air equipment'

Items tagged with 'energy efficient compressed air equipment'

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: End-to-end compressed air solutions including compressors, dryers, receivers, filters, and ring mains. We size capacity/pressure, leakage index, dew-point targets, and deliver clean, dry air to machines while reducing energy use and downtime. Compliances: OEM guidelines for air quality classes (ISO 8573), safety valves & piping practices; IS standards for pressure vessels where applicable. Benefits: Lower energy per m³, fewer breakdowns, longer tool life, and stable pressure across shifts. Why Choose Us: Data-led sizing, leakage audits, heat recovery options, condensate management, and P&IDs with clear O&M.

6814772a5d263414004dd4a4 Card 2

product image
Energy Management & Audit Services

Description: Performance evaluation of chillers, cooling towers, pumps, AHUs, VRF/VRV and ventilation to reduce kW/TR and improve comfort. We optimize water/air balances, reset strategies, schedules, filters, heat-recovery options, and propose VFDs and control logic to cut energy while maintaining IAQ. Compliances: ASHRAE benchmarking (reference), IS HVAC practices, IAQ guidance for ventilation. Benefits: Lower kWh, improved comfort, extended equipment life, better maintenance planning, reduced complaints. Why Choose Us: Hands-on balancing, realistic set-points, no fancy jargon—just actionable changes with measured before/after TR, ΔT and kW/TR.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones. Compliances: ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards. Benefits: Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning. Why Choose Us: Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design‑supply of storage tanks, air receivers, and heat exchangers with correct materials, thickness, nozzles, supports, and inspection openings. We deliver data sheets, drawings, fabrication QA, hydro/pneumatic tests, and traceable certificates. Compliances: IS/ASME for pressure parts; TEMA for exchangers; statutory approvals where required. Benefits: Fit‑for‑purpose, safe, maintainable equipment with documented design basis and long service life. Why Choose Us: Clear engineering deliverables, third‑party inspection options, and supervised installation/erection with alignment checks.

6814772a5d263414004dd4a4 Card 2

product image
Energy Management & Audit Services

Description: Comprehensive assessment of energy use across electrical, HVAC, utilities, lighting and processes to identify losses and savings potential. We benchmark consumption, profile loads, and quantify ROI-based measures to cut kWh, kVA and diesel consumption without compromising operations. Compliances: As per BEE audit guidelines, IS standards for measurement, and utility regulator norms for metering and billing analysis. Benefits: Lower bills (kWh/kVA), improved power factor, reduced demand charges, better equipment life, actionable CAPEX/OPEX plan with payback. Why Choose Us: Data-led approach with measurement & verification (M&V), practical recommendations, vendor-neutral BOQs, and post-implementation tracking.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: End‑to‑end ducting with correct gauges, leakage class, insulation and acoustics. We design for low-pressure drops, proper diffuser selection, throw and noise criteria to keep spaces comfortable and quiet. Compliances: SMACNA/IS duct standards; NBC/ASHRAE comfort and noise guidance. Benefits: Lower fan power, uniform temperatures, reduced noise/condensation, and clean finishes. Why Choose Us: Detail‑oriented shop drawings, hangers/supports, airtight joints, and site QA with leakage checks.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: Pressurization of staircases and lift lobbies to keep escape routes smoke‑free during fire events. We size fans, relief openings and controls to maintain code‑mandated pressures without door opening issues. Compliances: NBC smoke control provisions; local fire authority requirements. Benefits: Safer evacuation, better fire NOC compliance, integration with FA/PA logic. Why Choose Us: Proven designs with field commissioning, pressure tests, and interlocks aligned to alarm stages.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Process cooling networks designed for flow balance, NPSH, and temperature control—covering cooling towers, pumps, exchangers, and distribution. We minimize pumping power, ensure correct velocities, and plan chemical treatment points. Compliances: IS/ASHRAE guidance for cooling water; OEM guidelines for exchangers/pumps; water chemistry best practices. Benefits: Lower energy per m³, stable process temperatures, reduced fouling/scaling, and longer equipment life. Why Choose Us: Hydraulic modeling, debris management, treatment dosing, and well-documented O&M with KPIs for ΔT, approach, and cycles of concentration.

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Safe earthing networks and lightning protection designed per soil resistivity and building profile. We deliver earth grids, pits, bonding, SPD selection, and air‑termination/down‑conductors sized to handle faults and surges—protecting people, equipment, and data. Compliances: IS/IEC earthing & lightning standards; risk assessment per IEC 62305 where applicable. Benefits: Lower touch/step voltages, improved equipment safety, fewer nuisance trips, and better surge immunity. Why Choose Us: Measured soil tests, engineered layouts, resistance targets with test logs, and maintainable inspection chambers.

Still searching for
energy efficient compressed air equipment?