Customer:
Yotta Infrastructure
Project Category:
DATA CENTRE - TURNKEY FIRE FIGHTING PROJECT
Customer Requirement:
Strict adherence to NFPA & NBC standards using UL/FM-certified equipment Seamless integration with BMS and monitoring consoles Execution within short shutdown schedules with minimal disruption Clean-room safe installation, maintaining ESD and hygiene protocols Submission of as-built drawings and third-party approvals Coordination with MEP and IT vendors for synchronized execution Ensuring 100% compliance for fire and life safety audits before handover
Project Result:
COMPLETED SUCCESSFULLY
What we did:
Together with our business associate, Swastik Synergy Engineering Pvt. Ltd. (SSEPL), we executed a comprehensive range of systems that included: Fire Alarm and Detection System (FAS) integrated with BMS Pre-action Sprinkler Systems designed for high-sensitivity environments VESDA Early Warning Detection Systems for precise, continuous air sampling Clean Agent Suppression Systems (Novec 1230/FM-200) for server halls and UPS rooms CO₂ Flooding Systems for electrical panels and battery rooms Public Address & Voice Evacuation Systems Portable Fire Extinguishers and Fire Signages throughout the facility Fire Doors and Compartmentalization for Passive Protection Each system was tested, commissioned, and documented with as-built drawings, safety certifications, and audit-ready documentation in line with data centre standards.
Project Description
Data centres are the backbone of today’s digital economy — and even a few seconds of fire-related downtime can cause massive operational and financial losses. At Safety Saarthi Pvt. Ltd., we understand that fire safety for data centers isn’t just about compliance; it’s about maintaining continuous uptime, ensuring system redundancy, and executing precision. Our fire protection approach ensures complete coverage across server halls, UPS rooms, battery banks, control rooms, and critical IT zones — delivering end-to-end NFPA and NBC-compliant fire protection systems tailored for mission-critical data centres. We integrate fire alarm and detection systems, VESDA aspirating detection, clean agent suppression, CO₂ flooding systems, pre-action sprinkler systems, and public address & voice evacuation systems with the Building Management System (BMS) for comprehensive safety control. Each installation is executed to international standards, ensuring zero disruption, faster commissioning, and complete third-party compliance — making us one of India’s trusted partners for data centre fire safety solutions.
Project Budget:
3000000
Completion Date:
2024-06-24T00:00:00