Mumbai
+918956051383

Products

product image
Fire Protection Systems

Description: Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements. Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels. Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks. Compliance – IS 2189 – Fire Detection & Alarm Systems NFPA 72 – National Fire Alarm & Signaling Code NBC 2016 – Fire detection provisions for various occupancies Benefits – Early warning saves lives Automatic alarms with integration to suppression systems Compatible with NOC approval requirements Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.

Send Message
product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

Send Message
product image
Fire Suppression System

Description: Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability. Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications. Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels. Compliance – IS 6382 – CO₂ Fire Extinguishing Systems NFPA 12 – Carbon Dioxide Extinguishing Systems NBC 2016 – Provisions for gaseous suppression Benefits – Rapid fire knockdown No water damage to equipment Cost-effective suppression solution Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.

Send Message
product image
Fire Suppression System

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

Send Message
product image
Fire Suppression System

Our Inert Gas Fire Suppression System uses naturally occurring gases (Nitrogen, Argon, Inergen) to reduce oxygen levels and extinguish fires without damaging sensitive equipment. Compliant with IS 15493 and NFPA 2001, it is ideal for server rooms, archives, and control rooms. Benefits: 1. Non-conductive, residue-free 2. Safe for occupied spaces 3. Environmentally friendly Key Property: Gas Type – IG-01 / IG-55 / IG-541 Other Specifications: 1. Standard: IS 15493 / NFPA 2001 2. Storage Pressure: 150–200 bar 3. Cylinder Material: Seamless steel 4. Discharge Time: 60 seconds

Send Message
product image
Fire Suppression System

Description: A compact, fully autonomous suppression solution, our Tube-Based Fire Suppression System detects and extinguishes fires directly at the source. Compliant with IS 15302 and NFPA 2001, this system is ideal for electrical panels, CNC machines, engine bays, and confined enclosures. Features: 1.Flexible detection tube ruptures at heat source 2.Direct discharge onto fire 3.No external power supply needed Benefits: 1.Quick localized suppression 2.Minimal collateral damage 3.Easy installation in compact spaces Key Property: Activation Method – Heat Sensitive Tube Other Specifications: 1.Standard: IS 15302 / NFPA 2001 2.Agent Type: Clean agent / CO₂ 3.Operating Pressure: 10–20 bar 4.Tube Material: Nylon/polyamide high-temp resistant

Send Message
product image
Fire Protection Systems

Description: Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses. Key Components: Sprinkler heads (pendent, upright, sidewall) Distribution piping & alarm valves Water supply pumps & tanks Flow switches & monitoring systems Compliance: IS 15105 – Design & installation requirements for sprinkler systems NFPA 13 – Standard for installation of sprinkler systems NBC 2016 – Fire zone & occupancy-specific guidelines Why Choose Us: We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform. Benefits: Quick suppression at fire origin Reduces smoke & property damage Automatic activation without human intervention

Send Message
product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

Send Message
product image
Fire Suppression System

Description: Our Kitchen Fire Suppression System is specially designed to combat high-temperature cooking oil and grease fires. Built to UL 300 and NFPA 17A standards, it provides automatic detection and wet chemical discharge to suppress flames and cool surfaces. Applications: Hotels, restaurants, commercial kitchens, food processing plants. Benefits: 1. Prevents re-ignition 2. Fast, automatic activation 3. Safe for food environments 4. Key Property: Agent Type – Wet Chemical Other Specifications: 1. Standard: UL 300 / NFPA 17A 2. Discharge Time: < 10 seconds 3. Coverage: Based on hood size 4. Cylinder Material: Carbon steel, epoxy coated

Send Message

Subcategory Tags

kitchen fire suppression system UL 300 kitchen safety NFPA 17A wet chemical restaurant fire safety commercial kitchen hood protection automatic kitchen fire system turnkey kitchen fire protection cooking oil fire suppression fire NOC kitchen hotel fire safety system Fire hydrant system IS 13039 hydrant NFPA 24 hydrant NBC 2016 fire hydrant system Turnkey Fire fighting Solution fire NOC fire hydrant maintenance industrial fire safety system Govt. Approved Class A licensed Agency fire sprinkler system IS 15105 sprinklers NFPA 13 sprinkler NBC 2016 fire safety NBC Part 4 sprinkler installation turnkey fire safety project fire protection for buildings fire NOC compliance automatic sprinkler maintenance commercial fire sprinkler system tube suppression system IS 15302 suppression NFPA 2001 tube system electrical panel fire protection automatic fire suppression tube machine fire safety system turnkey suppression system localized fire suppression industrial fire safety inert gas fire suppression IS 15493 gas system NFPA 2001 IG-541 server room fire protection data center fire safety turnkey gas suppression system environment friendly fire protection non-conductive fire suppression fire NOC gas system archive fire protection system clean agent fire suppression system FM-200 fire suppression Novec 1230 suppression system FK-5-1-12 suppression system IS 15493 clean agent system NFPA 2001 clean agent system turnkey fire suppression solution government fire approval fire NOC clean agent data center fire safety system CO₂ fire suppression system IS 6382 CO₂ system NFPA 12 CO₂ system industrial fire suppression generator room fire protection cable tunnel CO₂ fire safety turnkey CO₂ suppression solution fire NOC CO₂ system industrial machinery fire safety Paint Shop fire Suppression System fire pump room system IS 15301 fire pump NFPA 20 fire pump installation NBC 2016 fire water supply diesel fire pump jockey fire pump turnkey fire pump room fire pump control panel pressure switch fire pump fire detection system fire alarm system IS 2189 NFPA 72 fire alarm system NBC 2016 fire detection conventional fire alarm system addressable fire alarm system smoke detector installation turnkey fire alarm system fire NOC alarm system
Phone Number

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Mumbai, Maharashtra, India

Mumbai, India, 400001