Low Voltage & Electronic Security Systems

Description: Electronic rodent repellent using ultrasonic transducers to deter rodent activity in cable galleries, server rooms, panels, warehouses and food areas. Can be combined with sealing/physical barriers and housekeeping SOPs for best results. Compliances: OEM installation guidelines; safety norms for ultrasonic devices; hygiene/housekeeping best practices. Benefits: Reduced cable chewing and equipment damage, fewer nuisance faults, improved hygiene and safety. Why Choose Us: Site mapping for emitter placement, correct power supplies, safe wiring, and periodic effectiveness checks.

6814772a5d263414004dd4a4 Card 2

product image
Low Voltage & Electronic Security Systems

Description: Role‑based access to doors, labs, server rooms and turnstiles with card/PIN/biometric/mobile credentials. We structure controllers, readers, locks, and door hardware so security is strong but day‑to‑day movement stays smooth. Compliances: Electrical & fire egress norms; data security best practices; ADA/accessibility guidance as applicable. Benefits: Audit trails, time‑based permissions, anti‑passback, and easier visitor management. Why Choose Us: Neat door schedules, wiring, fail‑safe/secure logic, and integration with HR/MS/attendance if required.

6814772a5d263414004dd4a4 Card 2

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Automation and controls for utilities/process—PLC/SCADA, field instruments (pressure, temperature, flow, level), control valves, and panels. We implement safe interlocks, logic, historian trends, and dashboards for reliable, data‑driven operations. Compliances: ISA/IEC standards for instrumentation & control; electrical safety per IS/IE Rules; industry best practices for alarm management. Benefits: Higher uptime, fewer operator errors, traceable data, remote visibility, and faster troubleshooting. Why Choose Us: Vendor‑neutral design, clean P&IDs, cause‑&‑effect matrices, FAT/SAT with IO checks, and structured documentation/training.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and build of process control panels integrating PLCs, MCCs, and VFDs with field instruments and drives. We deliver clean wiring, labeling, interlocks, and tested logic so operations can trust the pushbuttons and screens. Compliances: IS/IEC for panels and wiring; ISA practices for control & alarm philosophy; safety interlocks per process needs. Benefits: Reliable control, reduced downtime, clearer diagnostics, and easier expansion. Why Choose Us: Panel GA & wiring drawings, IO lists, cause‑&‑effect, FAT/SAT, and comprehensive O&M/training packs.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses. Key Components: Sprinkler heads (pendent, upright, sidewall) Distribution piping & alarm valves Water supply pumps & tanks Flow switches & monitoring systems Compliance: IS 15105 – Design & installation requirements for sprinkler systems NFPA 13 – Standard for installation of sprinkler systems NBC 2016 – Fire zone & occupancy-specific guidelines Why Choose Us: We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform. Benefits: Quick suppression at fire origin Reduces smoke & property damage Automatic activation without human intervention

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Our Inert Gas Fire Suppression System uses naturally occurring gases (Nitrogen, Argon, Inergen) to reduce oxygen levels and extinguish fires without damaging sensitive equipment. Compliant with IS 15493 and NFPA 2001, it is ideal for server rooms, archives, and control rooms. Benefits: 1. Non-conductive, residue-free 2. Safe for occupied spaces 3. Environmentally friendly Key Property: Gas Type – IG-01 / IG-55 / IG-541 Other Specifications: 1. Standard: IS 15493 / NFPA 2001 2. Storage Pressure: 150–200 bar 3. Cylinder Material: Seamless steel 4. Discharge Time: 60 seconds