Description: Site-wide storm water systems handling peak monsoon flows via catch pits, gratings, roadside drains, and underground pipes to outfalls/recharge structures. We design gradients and capacities to prevent flooding, waterlogging, and damage to roads, basements, or landscaping.
Compliances: Local municipal storm-water norms; NBC/CPHEEO guidance for drainage design.
Benefits: Flood-safe site, longer pavement life, clean landscaped areas, reduced complaints and downtime.
Why Choose Us: Accurate hydraulic calculations, proper silt control, accessible chambers, and as-built levels that actually match site contours.
The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies.
Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system.
Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings.
Compliance –
IS 15301 – Fire Pump Installation
NFPA 20 – Installation of Fire Pumps
NBC 2016 – Fire water supply requirements
Benefits –
Continuous water availability
Fully automated with control panel
Integrated monitoring for reliability
Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.
Description:
Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks.
Compliances:
PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable.
Benefits:
Reliable supply, spill/leak minimization, improved burner performance, safer operation.
Why Choose Us:
Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.
*Description*: Complete SWV systems from fixture traps to soil/waste stacks, vents, and external collection lines up to the manhole/sewer or STP. We ensure gradients, venting, and cleanouts are correct so blockages and odors are minimized. External networks are laid with proper bedding, levels, and access chambers for easy maintenance.
Compliances: NBC 2016 plumbing provisions; local authority sewer connection norms; good engineering practices for traps/vents/gradients.
Benefits: Fewer blockages, no odor complaints, long service life, easy maintenance with planned cleanouts and chambers.
Why Choose Us: Thoughtful routing that respects architecture/MEP clashes, neat shaft detailing, and handover with line-by-line test records.
Description: Capture and utilize roof/terrace runoff through down-take pipes, filters, silt traps, storage, and recharge pits/bores or reuse loops. We size components based on rainfall intensity and roof area so your system actually works during monsoons and reduces dependency on tankers/municipal supply.
Compliances: Local development authority RWH by-laws; NBC guidance on water conservation; CPHEEO practices.
Benefits: Lower freshwater bills, improved groundwater recharge, ESG/green points, reduced storm drain burden.
Why Choose Us: Correct hydraulic sizing, debris/silt control, safe overflow paths, and easy-to-maintain filter layouts with documented O&M.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Description:
Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection.
Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment.
Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels.
Compliance –
IS 15493 – Clean Agent Extinguishing Systems
NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems
NBC 2016 – Fire protection for special occupancies
Benefits –
Environmentally sustainable
Non-conductive and residue-free
Safe for occupied areas
Quick activation within seconds
Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description:
Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses.
Key Components:
Sprinkler heads (pendent, upright, sidewall)
Distribution piping & alarm valves
Water supply pumps & tanks
Flow switches & monitoring systems
Compliance:
IS 15105 – Design & installation requirements for sprinkler systems
NFPA 13 – Standard for installation of sprinkler systems
NBC 2016 – Fire zone & occupancy-specific guidelines
Why Choose Us:
We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform.
Benefits:
Quick suppression at fire origin
Reduces smoke & property damage
Automatic activation without human intervention
Still searching for roadside drain and grate system?