Pune
08042755939
+918956051383

'plc scada field instrumentation solutions'

Items tagged with 'plc scada field instrumentation solutions'

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Automation and controls for utilities/process—PLC/SCADA, field instruments (pressure, temperature, flow, level), control valves, and panels. We implement safe interlocks, logic, historian trends, and dashboards for reliable, data‑driven operations. Compliances: ISA/IEC standards for instrumentation & control; electrical safety per IS/IE Rules; industry best practices for alarm management. Benefits: Higher uptime, fewer operator errors, traceable data, remote visibility, and faster troubleshooting. Why Choose Us: Vendor‑neutral design, clean P&IDs, cause‑&‑effect matrices, FAT/SAT with IO checks, and structured documentation/training.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor. Compliances: - NBC 2016 – Part 4 (Fire & Life Safety) - IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets - IS 2189 / NFPA 72 for fire detection & alarm (when in scope) - NFPA 20 / NFPA 13 / NFPA 2001 (as applicable) - Local CFO / Fire Brigade requirements for provisional and final NOC Benefits: - One-point accountability – no multi-vendor disputes - Faster fire NOC because drawings, test certificates and demonstrations are handled together - Standardised and approved make materials → better reliability - Installation with testing (hydro, flushing, pump trials) and complete O&M handover - Option to continue with AMC from the same team Why Choose Us: - Govt-approved / class-A fire & safety contractor with multi-sector experience - Fire projects executed in industrial, healthcare, warehousing and commercial facilities - We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority - We train your operators on hydrant/sprinkler/pump panel so the system is actually usable - Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and build of process control panels integrating PLCs, MCCs, and VFDs with field instruments and drives. We deliver clean wiring, labeling, interlocks, and tested logic so operations can trust the pushbuttons and screens. Compliances: IS/IEC for panels and wiring; ISA practices for control & alarm philosophy; safety interlocks per process needs. Benefits: Reliable control, reduced downtime, clearer diagnostics, and easier expansion. Why Choose Us: Panel GA & wiring drawings, IO lists, cause‑&‑effect, FAT/SAT, and comprehensive O&M/training packs.

6814772a5d263414004dd4a4 Card 2

product image
Water & Wastewater Treatment Systems (WTP/ETP/STP)

Description: ETPs handle industrial wastewater containing oils, solids, heavy metals, and complex organics. We combine equalization, pH correction, coagulation/DAF, and aerobic/anaerobic biological treatment with tertiary polishing (UF/RO where needed) to meet CPCB/SPCB discharge or reuse targets. Our approach starts with treatability testing to pick the right process that is stable, maintainable, and cost-effective. Compliances: CPCB/SPCB limits; industry-specific guidelines and client water balance targets. Benefits: Statutory compliance with documented results, reuse potential, reduced freshwater intake, and optimized OPEX through correct chemistry and automation. Why Choose Us: Data-driven design, robust sludge management (filter press/centrifuge), PLC/SCADA, commissioning with KPI acceptance, and clear O&M SOPs for operators.

6814772a5d263414004dd4a4 Card 2

product image
Water & Wastewater Treatment Systems (WTP/ETP/STP)

Description: RO systems reduce TDS and specific ions to deliver consistent process or utility water for beverages, electronics, pharma pre-treatment, and boiler make-up. We engineer the right pretreatment (PSF/ACF/UF), antiscalant dosing, and CIP strategy to protect membranes and maximize recovery—cutting water and energy costs. Skid-mounted designs fit existing plants without civil rework, and controls provide real-time quality monitoring. Compliances: Meets process specifications and membrane OEM guidelines; references IS 10500 for potable usage targets when required. Benefits: Predictable low-TDS water, longer membrane life, lower scaling/fouling risk, modular capacity upgrades, and lower overall OPEX. Why Choose Us: Feed characterization, membrane selection, energy-efficient pumps/VFDs, PLC/SCADA with alarm logging, and CIP provisions ensure dependable, serviceable systems.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements. Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels. Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks. Compliance – IS 2189 – Fire Detection & Alarm Systems NFPA 72 – National Fire Alarm & Signaling Code NBC 2016 – Fire detection provisions for various occupancies Benefits – Early warning saves lives Automatic alarms with integration to suppression systems Compatible with NOC approval requirements Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability. Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications. Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels. Compliance – IS 6382 – CO₂ Fire Extinguishing Systems NFPA 12 – Carbon Dioxide Extinguishing Systems NBC 2016 – Provisions for gaseous suppression Benefits – Rapid fire knockdown No water damage to equipment Cost-effective suppression solution Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.

Still searching for
plc scada field instrumentation solutions?