Pune
08042755939
+918956051383

'oil free air compressor with dryer'

Items tagged with 'oil free air compressor with dryer'

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: End-to-end compressed air solutions including compressors, dryers, receivers, filters, and ring mains. We size capacity/pressure, leakage index, dew-point targets, and deliver clean, dry air to machines while reducing energy use and downtime. Compliances: OEM guidelines for air quality classes (ISO 8573), safety valves & piping practices; IS standards for pressure vessels where applicable. Benefits: Lower energy per m³, fewer breakdowns, longer tool life, and stable pressure across shifts. Why Choose Us: Data-led sizing, leakage audits, heat recovery options, condensate management, and P&IDs with clear O&M.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: Pressurization of staircases and lift lobbies to keep escape routes smoke‑free during fire events. We size fans, relief openings and controls to maintain code‑mandated pressures without door opening issues. Compliances: NBC smoke control provisions; local fire authority requirements. Benefits: Safer evacuation, better fire NOC compliance, integration with FA/PA logic. Why Choose Us: Proven designs with field commissioning, pressure tests, and interlocks aligned to alarm stages.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones. Compliances: ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards. Benefits: Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning. Why Choose Us: Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: Code‑compliant ventilation and exhaust for basements, kitchens, toilets and process areas. We size fans/ducts, ensure correct air changes, smoke extraction logic where required, and deliver low‑loss layouts with access for maintenance. Compliances: NBC ventilation & smoke control provisions, IS/ASHRAE guidance, local fire approvals where applicable. Benefits: Better IAQ, controlled odors/fumes, safer egress during smoke events, and lower fan power. Why Choose Us: Balanced, maintainable routing with sound attenuation, tested airflow, and clear as‑builts.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: End‑to‑end ducting with correct gauges, leakage class, insulation and acoustics. We design for low-pressure drops, proper diffuser selection, throw and noise criteria to keep spaces comfortable and quiet. Compliances: SMACNA/IS duct standards; NBC/ASHRAE comfort and noise guidance. Benefits: Lower fan power, uniform temperatures, reduced noise/condensation, and clean finishes. Why Choose Us: Detail‑oriented shop drawings, hangers/supports, airtight joints, and site QA with leakage checks.

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Safe earthing networks and lightning protection designed per soil resistivity and building profile. We deliver earth grids, pits, bonding, SPD selection, and air‑termination/down‑conductors sized to handle faults and surges—protecting people, equipment, and data. Compliances: IS/IEC earthing & lightning standards; risk assessment per IEC 62305 where applicable. Benefits: Lower touch/step voltages, improved equipment safety, fewer nuisance trips, and better surge immunity. Why Choose Us: Measured soil tests, engineered layouts, resistance targets with test logs, and maintainable inspection chambers.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: DM plants remove dissolved salts to produce very low-conductivity water for boilers, process chemistry, pharma utilities, and electronics rinsing. Using ion-exchange resins in Cation/Anion (two-bed) or mixed-bed polishing, we consistently achieve the purity needed to prevent scaling, corrosion, and product contamination. Where operating cost matters, we pair RO + DM to cut chemical use and waste volume, while keeping a compact footprint and easy maintenance. Compliances: Meets customer-specified conductivity/silica limits; aligns with Good Engineering Practices, resin vendor guidelines, and IS process water references. Benefits: High-purity water for critical applications; stable boiler efficiency, reduced blowdown; predictable resin life and optimized regeneration; skid designs for fast installation. Why Choose Us: Correct resin selection and sizing, safe regeneration interlocks, clear P&IDs/O&M, operator training, and performance benchmarking ensure you hit quality targets from day one.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

Still searching for