Pune
08042755939
+918956051383

'medium voltage rmu panels and busbar'

Items tagged with 'medium voltage rmu panels and busbar'

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Robust high‑tension distribution engineered for reliability and safety—comprising incoming/outgoing feeders, protection relays, metering, and interlocks. We design and supply indoor/outdoor HT panels, RMUs and switchgear with correct fault level calculations, protection coordination, and compliance to DISCOM/CEIG requirements. Suitable for industrial plants, campuses, hospitals, IT parks, and logistics hubs. Compliances: IS/IEC for switchgear & controlgear; utility/DISCOM standards; CEIG approval norms; earthing & clearances per IS/IE Rules. Benefits: Higher uptime, safer operations, correct protection discrimination, scalable bays, and simpler statutory approvals. Why Choose Us: Accurate short‑circuit studies, relay settings, GA/SLD documentation, factory testing, site SAT/commissioning, and CEIG liaison support.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and build of process control panels integrating PLCs, MCCs, and VFDs with field instruments and drives. We deliver clean wiring, labeling, interlocks, and tested logic so operations can trust the pushbuttons and screens. Compliances: IS/IEC for panels and wiring; ISA practices for control & alarm philosophy; safety interlocks per process needs. Benefits: Reliable control, reduced downtime, clearer diagnostics, and easier expansion. Why Choose Us: Panel GA & wiring drawings, IO lists, cause‑&‑effect, FAT/SAT, and comprehensive O&M/training packs.

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Custom LT panel boards built for safe, maintainable power distribution—PCC for main distribution, MCC for motor feeders, APFC for power factor, and DG‑to‑mains synchronization for reliable backup. Designed with correct busbar sizing, fault withstand, heat dissipation, cable management and interlocking. Compliances: IS/IEC panel standards; IE Rules for clearances & safety; DISCOM metering norms. Benefits: Lower losses, improved PF (reduced penalties), better selectivity, clean wiring for faster maintenance, and future expandability. Why Choose Us: Engineering drawings, bill of materials with reputed makes, FAT, site installation & SAT, with detailed O&M and spares mapping.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements. Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels. Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks. Compliance – IS 2189 – Fire Detection & Alarm Systems NFPA 72 – National Fire Alarm & Signaling Code NBC 2016 – Fire detection provisions for various occupancies Benefits – Early warning saves lives Automatic alarms with integration to suppression systems Compatible with NOC approval requirements Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: A compact, fully autonomous suppression solution, our Tube-Based Fire Suppression System detects and extinguishes fires directly at the source. Compliant with IS 15302 and NFPA 2001, this system is ideal for electrical panels, CNC machines, engine bays, and confined enclosures. Features: 1.Flexible detection tube ruptures at heat source 2.Direct discharge onto fire 3.No external power supply needed Benefits: 1.Quick localized suppression 2.Minimal collateral damage 3.Easy installation in compact spaces Key Property: Activation Method – Heat Sensitive Tube Other Specifications: 1.Standard: IS 15302 / NFPA 2001 2.Agent Type: Clean agent / CO₂ 3.Operating Pressure: 10–20 bar 4.Tube Material: Nylon/polyamide high-temp resistant

6814772a5d263414004dd4a4 Card 2

product image
Low Voltage & Electronic Security Systems

Description: Electronic rodent repellent using ultrasonic transducers to deter rodent activity in cable galleries, server rooms, panels, warehouses and food areas. Can be combined with sealing/physical barriers and housekeeping SOPs for best results. Compliances: OEM installation guidelines; safety norms for ultrasonic devices; hygiene/housekeeping best practices. Benefits: Reduced cable chewing and equipment damage, fewer nuisance faults, improved hygiene and safety. Why Choose Us: Site mapping for emitter placement, correct power supplies, safe wiring, and periodic effectiveness checks.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks. Compliances: PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable. Benefits: Reliable supply, spill/leak minimization, improved burner performance, safer operation. Why Choose Us: Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.

Still searching for
medium voltage rmu panels and busbar?