Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042755939 (International callers) or 08042755939 (Indian callers).
Description:
End‑to‑end ducting with correct gauges, leakage class, insulation and acoustics. We design for low-pressure drops, proper diffuser selection, throw and noise criteria to keep spaces comfortable and quiet.
Compliances:
SMACNA/IS duct standards; NBC/ASHRAE comfort and noise guidance.
Benefits:
Lower fan power, uniform temperatures, reduced noise/condensation, and clean finishes.
Why Choose Us:
Detail‑oriented shop drawings, hangers/supports, airtight joints, and site QA with leakage checks.
Description:
High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones.
Compliances:
ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards.
Benefits:
Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning.
Why Choose Us:
Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.
Description: STPs treat domestic wastewater from residential, commercial, healthcare, and IT parks to meet discharge/reuse norms. We design compact, odor-controlled plants using MBBR/SBR/MBR to achieve consistent BOD, COD, and TSS reduction. Treated water can be reused for flushing, landscaping, or HVAC make-up, cutting freshwater bills and improving sustainability scores.
Compliances: CPCB / Local Urban Body standards; NBC guidance for plumbing and reuse.
Benefits: Lower freshwater dependency, stable effluent quality, small footprint options, easy operation, and potential green building credits.
Why Choose Us: Complete civil + electro-mechanical delivery, automation with alarms, trial run & stabilization, operator training, and reuse integration (tanks/boosters).
Description: These systems condition raw water before it enters boilers, cooling towers, RO units, or process lines. Softening removes hardness (Ca/Mg) to stop scaling; Pressure Sand Filters (PSF) remove suspended solids and turbidity; Activated Carbon Filters (ACF) control color, odor, chlorine, and organics; Iron/Manganese filters protect downstream membranes and equipment. The result is longer equipment life, fewer shutdowns, and stable downstream performance.
Compliances: Designed to meet target water specs derived from boiler/HVAC/RO supplier recommendations and IS references.
Benefits: Protects capital equipment, reduces chemical and energy waste, improves RO life and heat-exchange efficiency, and offers low-CAPEX reliability.
Why Choose Us: Correct media sizing and EBCT, auto/PLC valve options, duplexing for zero downtime, and lifecycle spares support—delivered as neat skid packages.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description:
Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses.
Key Components:
Sprinkler heads (pendent, upright, sidewall)
Distribution piping & alarm valves
Water supply pumps & tanks
Flow switches & monitoring systems
Compliance:
IS 15105 – Design & installation requirements for sprinkler systems
NFPA 13 – Standard for installation of sprinkler systems
NBC 2016 – Fire zone & occupancy-specific guidelines
Why Choose Us:
We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform.
Benefits:
Quick suppression at fire origin
Reduces smoke & property damage
Automatic activation without human intervention
The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies.
Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system.
Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings.
Compliance –
IS 15301 – Fire Pump Installation
NFPA 20 – Installation of Fire Pumps
NBC 2016 – Fire water supply requirements
Benefits –
Continuous water availability
Fully automated with control panel
Integrated monitoring for reliability
Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.
Still searching for low pressure hvac duct design services?