Pune
08042755939
+918956051383

'lift lobby smoke free pressurization units'

Items tagged with 'lift lobby smoke free pressurization units'

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: Pressurization of staircases and lift lobbies to keep escape routes smoke‑free during fire events. We size fans, relief openings and controls to maintain code‑mandated pressures without door opening issues. Compliances: NBC smoke control provisions; local fire authority requirements. Benefits: Safer evacuation, better fire NOC compliance, integration with FA/PA logic. Why Choose Us: Proven designs with field commissioning, pressure tests, and interlocks aligned to alarm stages.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

6814772a5d263414004dd4a4 Card 2

product image
Plumbing & Drainage Systems

Description: Engineered sumps, lift stations, and pump rooms for water, flushing, storm and sewage transfer. We size pumps, NPSH, suction headers, and controls (float/pressure/BMS) so starts/stops are smooth, cavitation is avoided, and standby logic is fail-safe. Delivered with valves, NRVs, strainers, level instrumentation, and safety features. Compliances: NBC plumbing guidance; IS practices for pumps/valves/electrical; local electrical approvals as applicable. Benefits: Reliable transfer without dry-run or overflow, lower energy usage with correct duty points, easy service access and documented logic. Why Choose Us: We combine hydraulics with controls—proper cable trays, ventilation, sump access, and clear SOPs—so facilities can run the system worry-free.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Corporate Fire & Safety Training is our training-division service for organisations that want their people to actually know how to respond, not just attend a PPT. Modules are built from our real project experience and delivered using live demonstrations, hands-on extinguisher use, mock drills and role-play for ERT members. We tailor content to your industry (manufacturing, construction, food, IT/ITES, pharma, healthcare, hospitality). Training Modules : - Basic fire prevention & firefighting - Advanced / system-based firefighting (hydrant, sprinkler, gas suppression) - First aid & basic medical emergencies (CPR, bandaging, lifting) - Evacuation mock drill / ERT formation - Construction site safety - Behaviour-based safety (BBS) - Defensive driving / road safety - Food safety / hygiene / GMP-HACCP awareness - POSH – Prevention of sexual harassment at workplace - Social engineering / human-factor security Compliances: - Supports NBC requirements for fire training & drills - POSH awareness as per POSH Act 2013 (awareness level) - Supports ISO 45001 / customer / buyer / factory inspector audit observations Benefits: - Improves real emergency response time - Reduces panic & confusion during fire/medical incidents - Provides training records for audits, clients and EHS teams - Builds safety culture and accountability on shopfloor/site Why Choose Us: - We are an execution company first – so training is practical and system-oriented - Trainers from fire/EHS/medical background - Can train on your actual installed systems (your hydrant, your panel) - We provide attendance sheets, photos and training report - Available across Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses. Key Components: Sprinkler heads (pendent, upright, sidewall) Distribution piping & alarm valves Water supply pumps & tanks Flow switches & monitoring systems Compliance: IS 15105 – Design & installation requirements for sprinkler systems NFPA 13 – Standard for installation of sprinkler systems NBC 2016 – Fire zone & occupancy-specific guidelines Why Choose Us: We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform. Benefits: Quick suppression at fire origin Reduces smoke & property damage Automatic activation without human intervention

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements. Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels. Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks. Compliance – IS 2189 – Fire Detection & Alarm Systems NFPA 72 – National Fire Alarm & Signaling Code NBC 2016 – Fire detection provisions for various occupancies Benefits – Early warning saves lives Automatic alarms with integration to suppression systems Compatible with NOC approval requirements Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Our Inert Gas Fire Suppression System uses naturally occurring gases (Nitrogen, Argon, Inergen) to reduce oxygen levels and extinguish fires without damaging sensitive equipment. Compliant with IS 15493 and NFPA 2001, it is ideal for server rooms, archives, and control rooms. Benefits: 1. Non-conductive, residue-free 2. Safe for occupied spaces 3. Environmentally friendly Key Property: Gas Type – IG-01 / IG-55 / IG-541 Other Specifications: 1. Standard: IS 15493 / NFPA 2001 2. Storage Pressure: 150–200 bar 3. Cylinder Material: Seamless steel 4. Discharge Time: 60 seconds

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Limit smoke and flame spread with rated fire doors, fire curtains and certified fire‑stopping for cable/pipe penetrations. Proper compartmentation buys evacuation time and protects escape routes and assets. Compliances: NBC 2016 passive fire provisions; manufacturer test certificates/UL/BS/IS as applicable. Benefits: Better life safety, smaller fire/smoke spread, improved NOC/insurance compliance, cleaner post‑incident restoration. Why Choose Us: Detailing that matches approvals, correct materials (intumescent sealants, collars, wraps), site inspections and closure documentation. Other specifications:

Still searching for