6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones. Compliances: ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards. Benefits: Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning. Why Choose Us: Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Robust high‑tension distribution engineered for reliability and safety—comprising incoming/outgoing feeders, protection relays, metering, and interlocks. We design and supply indoor/outdoor HT panels, RMUs and switchgear with correct fault level calculations, protection coordination, and compliance to DISCOM/CEIG requirements. Suitable for industrial plants, campuses, hospitals, IT parks, and logistics hubs. Compliances: IS/IEC for switchgear & controlgear; utility/DISCOM standards; CEIG approval norms; earthing & clearances per IS/IE Rules. Benefits: Higher uptime, safer operations, correct protection discrimination, scalable bays, and simpler statutory approvals. Why Choose Us: Accurate short‑circuit studies, relay settings, GA/SLD documentation, factory testing, site SAT/commissioning, and CEIG liaison support.

6814772a5d263414004dd4a4 Card 2

product image
Turnkey Solutions

Description: Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor. Compliances: - NBC 2016 – Part 4 (Fire & Life Safety) - IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets - IS 2189 / NFPA 72 for fire detection & alarm (when in scope) - NFPA 20 / NFPA 13 / NFPA 2001 (as applicable) - Local CFO / Fire Brigade requirements for provisional and final NOC Benefits: - One-point accountability – no multi-vendor disputes - Faster fire NOC because drawings, test certificates and demonstrations are handled together - Standardised and approved make materials → better reliability - Installation with testing (hydro, flushing, pump trials) and complete O&M handover - Option to continue with AMC from the same team Why Choose Us: - Govt-approved / class-A fire & safety contractor with multi-sector experience - Fire projects executed in industrial, healthcare, warehousing and commercial facilities - We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority - We train your operators on hydrant/sprinkler/pump panel so the system is actually usable - Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability. Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications. Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels. Compliance – IS 6382 – CO₂ Fire Extinguishing Systems NFPA 12 – Carbon Dioxide Extinguishing Systems NBC 2016 – Provisions for gaseous suppression Benefits – Rapid fire knockdown No water damage to equipment Cost-effective suppression solution Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks. Compliances: PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable. Benefits: Reliable supply, spill/leak minimization, improved burner performance, safer operation. Why Choose Us: Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.

6814772a5d263414004dd4a4 Card 2

product image
Medium & Low Voltage Electrical Systems

Description: Outdoor and industrial lighting engineered for lux uniformity, safety, and energy efficiency. We perform lighting layout, pole selection, optics, and controls—covering streets, yards, factories, and warehouses. Compliances: IS lighting practices; local electrical codes; recommended lux levels per application. Benefits: Better visibility & safety, lower energy bills, reduced maintenance with long‑life luminaires. Why Choose Us: Lighting calculations, correct optics, surge‑protected drivers, and scalable control options from simple timers to IoT.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection. Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment. Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels. Compliance – IS 15493 – Clean Agent Extinguishing Systems NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems NBC 2016 – Fire protection for special occupancies Benefits – Environmentally sustainable Non-conductive and residue-free Safe for occupied areas Quick activation within seconds Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.

Still searching for