Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042755939 (International callers) or 08042755939 (Indian callers).
Description:
End-to-end compressed air solutions including compressors, dryers, receivers, filters, and ring mains. We size capacity/pressure, leakage index, dew-point targets, and deliver clean, dry air to machines while reducing energy use and downtime.
Compliances:
OEM guidelines for air quality classes (ISO 8573), safety valves & piping practices; IS standards for pressure vessels where applicable.
Benefits:
Lower energy per m³, fewer breakdowns, longer tool life, and stable pressure across shifts.
Why Choose Us:
Data-led sizing, leakage audits, heat recovery options, condensate management, and P&IDs with clear O&M.
Description:
High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones.
Compliances:
ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards.
Benefits:
Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning.
Why Choose Us:
Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.
Description:
Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor.
Compliances:
- NBC 2016 – Part 4 (Fire & Life Safety)
- IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets
- IS 2189 / NFPA 72 for fire detection & alarm (when in scope)
- NFPA 20 / NFPA 13 / NFPA 2001 (as applicable)
- Local CFO / Fire Brigade requirements for provisional and final NOC
Benefits:
- One-point accountability – no multi-vendor disputes
- Faster fire NOC because drawings, test certificates and demonstrations are handled together
- Standardised and approved make materials → better reliability
- Installation with testing (hydro, flushing, pump trials) and complete O&M handover
- Option to continue with AMC from the same team
Why Choose Us:
- Govt-approved / class-A fire & safety contractor with multi-sector experience
- Fire projects executed in industrial, healthcare, warehousing and commercial facilities
- We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority
- We train your operators on hydrant/sprinkler/pump panel so the system is actually usable
- Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India
The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies.
Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system.
Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings.
Compliance –
IS 15301 – Fire Pump Installation
NFPA 20 – Installation of Fire Pumps
NBC 2016 – Fire water supply requirements
Benefits –
Continuous water availability
Fully automated with control panel
Integrated monitoring for reliability
Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.
Description:
Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements.
Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels.
Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks.
Compliance –
IS 2189 – Fire Detection & Alarm Systems
NFPA 72 – National Fire Alarm & Signaling Code
NBC 2016 – Fire detection provisions for various occupancies
Benefits –
Early warning saves lives
Automatic alarms with integration to suppression systems
Compatible with NOC approval requirements
Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.
Description:
Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability.
Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications.
Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels.
Compliance –
IS 6382 – CO₂ Fire Extinguishing Systems
NFPA 12 – Carbon Dioxide Extinguishing Systems
NBC 2016 – Provisions for gaseous suppression
Benefits –
Rapid fire knockdown
No water damage to equipment
Cost-effective suppression solution
Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.
Description:
Outdoor and industrial lighting engineered for lux uniformity, safety, and energy efficiency. We perform lighting layout, pole selection, optics, and controls—covering streets, yards, factories, and warehouses.
Compliances:
IS lighting practices; local electrical codes; recommended lux levels per application.
Benefits:
Better visibility & safety, lower energy bills, reduced maintenance with long‑life luminaires.
Why Choose Us:
Lighting calculations, correct optics, surge‑protected drivers, and scalable control options from simple timers to IoT.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Still searching for industrial compressed air system solutions?
Gat No. 447, Maitri Park, Plot No. E20, E30, Khadi Machine Road, Moshi, Pimpri-Chinchwad,