6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: A compact, fully autonomous suppression solution, our Tube-Based Fire Suppression System detects and extinguishes fires directly at the source. Compliant with IS 15302 and NFPA 2001, this system is ideal for electrical panels, CNC machines, engine bays, and confined enclosures. Features: 1.Flexible detection tube ruptures at heat source 2.Direct discharge onto fire 3.No external power supply needed Benefits: 1.Quick localized suppression 2.Minimal collateral damage 3.Easy installation in compact spaces Key Property: Activation Method – Heat Sensitive Tube Other Specifications: 1.Standard: IS 15302 / NFPA 2001 2.Agent Type: Clean agent / CO₂ 3.Operating Pressure: 10–20 bar 4.Tube Material: Nylon/polyamide high-temp resistant

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our Kitchen Fire Suppression System is specially designed to combat high-temperature cooking oil and grease fires. Built to UL 300 and NFPA 17A standards, it provides automatic detection and wet chemical discharge to suppress flames and cool surfaces. Applications: Hotels, restaurants, commercial kitchens, food processing plants. Benefits: 1. Prevents re-ignition 2. Fast, automatic activation 3. Safe for food environments 4. Key Property: Agent Type – Wet Chemical Other Specifications: 1. Standard: UL 300 / NFPA 17A 2. Discharge Time: < 10 seconds 3. Coverage: Based on hood size 4. Cylinder Material: Carbon steel, epoxy coated

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

6814772a5d263414004dd4a4 Card 2

product image
Fire Protection Systems

Description: Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability. Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications. Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels. Compliance – IS 6382 – CO₂ Fire Extinguishing Systems NFPA 12 – Carbon Dioxide Extinguishing Systems NBC 2016 – Provisions for gaseous suppression Benefits – Rapid fire knockdown No water damage to equipment Cost-effective suppression solution Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.

6814772a5d263414004dd4a4 Card 2

product image
Low Voltage & Electronic Security Systems

Description: Early detection of water leaks in data centers, server rooms, UPS rooms, laboratories, archives and false floors using spot sensors or addressable leak‑detection cables. The system pinpoints location, triggers local/buzzer alarms, and can notify BMS to shut down sensitive equipment or close motorized valves. Compliances: Best practices for mission‑critical facilities; OEM sensor/controller guidelines; integration per BMS protocols. Benefits: Prevents damage to electrical/electronics, reduces downtime, and protects high‑value rooms and records. Why Choose Us: Clean cable routing, address mapping, supervised loops, and tested alarms with clear as‑builts and maintenance SOPs.

6814772a5d263414004dd4a4 Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones. Compliances: ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards. Benefits: Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning. Why Choose Us: Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks. Compliances: PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable. Benefits: Reliable supply, spill/leak minimization, improved burner performance, safer operation. Why Choose Us: Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.

6814772a5d263414004dd4a4 Card 2

product image
Industrial Utilities & Process Control Systems

Description: Automation and controls for utilities/process—PLC/SCADA, field instruments (pressure, temperature, flow, level), control valves, and panels. We implement safe interlocks, logic, historian trends, and dashboards for reliable, data‑driven operations. Compliances: ISA/IEC standards for instrumentation & control; electrical safety per IS/IE Rules; industry best practices for alarm management. Benefits: Higher uptime, fewer operator errors, traceable data, remote visibility, and faster troubleshooting. Why Choose Us: Vendor‑neutral design, clean P&IDs, cause‑&‑effect matrices, FAT/SAT with IO checks, and structured documentation/training.

Still searching for
high temperature resistant nylon tube system?