Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042755939 (International callers) or 08042755939 (Indian callers).
Description:
Efficient steam generation & distribution with correct pipe sizing, traps, PRVs, and condensate return to improve boiler efficiency. We optimize headers, drip legs, and insulation for process stability and lower fuel bills.
Compliances:
Boiler Act and IBR where applicable; IS piping & insulation practices; safety valve and trapping guidelines.
Benefits:
Stable process temperatures, reduced flash losses, better boiler efficiency, and safer operation.
Why Choose Us:
Audited layouts, trap surveys, heat balancing, and easy-to-maintain drip/strainer stations with clear tagging.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Description:
Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks.
Compliances:
PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable.
Benefits:
Reliable supply, spill/leak minimization, improved burner performance, safer operation.
Why Choose Us:
Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.
Description:
Design‑supply of storage tanks, air receivers, and heat exchangers with correct materials, thickness, nozzles, supports, and inspection openings. We deliver data sheets, drawings, fabrication QA, hydro/pneumatic tests, and traceable certificates.
Compliances:
IS/ASME for pressure parts; TEMA for exchangers; statutory approvals where required.
Benefits:
Fit‑for‑purpose, safe, maintainable equipment with documented design basis and long service life.
Why Choose Us:
Clear engineering deliverables, third‑party inspection options, and supervised installation/erection with alignment checks.
Description:
Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor.
Compliances:
- NBC 2016 – Part 4 (Fire & Life Safety)
- IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets
- IS 2189 / NFPA 72 for fire detection & alarm (when in scope)
- NFPA 20 / NFPA 13 / NFPA 2001 (as applicable)
- Local CFO / Fire Brigade requirements for provisional and final NOC
Benefits:
- One-point accountability – no multi-vendor disputes
- Faster fire NOC because drawings, test certificates and demonstrations are handled together
- Standardised and approved make materials → better reliability
- Installation with testing (hydro, flushing, pump trials) and complete O&M handover
- Option to continue with AMC from the same team
Why Choose Us:
- Govt-approved / class-A fire & safety contractor with multi-sector experience
- Fire projects executed in industrial, healthcare, warehousing and commercial facilities
- We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority
- We train your operators on hydrant/sprinkler/pump panel so the system is actually usable
- Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India
Description:
Corporate Fire & Safety Training is our training-division service for organisations that want their people to actually know how to respond, not just attend a PPT. Modules are built from our real project experience and delivered using live demonstrations, hands-on extinguisher use, mock drills and role-play for ERT members. We tailor content to your industry (manufacturing, construction, food, IT/ITES, pharma, healthcare, hospitality).
Training Modules :
- Basic fire prevention & firefighting
- Advanced / system-based firefighting (hydrant, sprinkler, gas suppression)
- First aid & basic medical emergencies (CPR, bandaging, lifting)
- Evacuation mock drill / ERT formation
- Construction site safety
- Behaviour-based safety (BBS)
- Defensive driving / road safety
- Food safety / hygiene / GMP-HACCP awareness
- POSH – Prevention of sexual harassment at workplace
- Social engineering / human-factor security
Compliances:
- Supports NBC requirements for fire training & drills
- POSH awareness as per POSH Act 2013 (awareness level)
- Supports ISO 45001 / customer / buyer / factory inspector audit observations
Benefits:
- Improves real emergency response time
- Reduces panic & confusion during fire/medical incidents
- Provides training records for audits, clients and EHS teams
- Builds safety culture and accountability on shopfloor/site
Why Choose Us:
- We are an execution company first – so training is practical and system-oriented
- Trainers from fire/EHS/medical background
- Can train on your actual installed systems (your hydrant, your panel)
- We provide attendance sheets, photos and training report
- Available across Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Description:
Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection.
Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment.
Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels.
Compliance –
IS 15493 – Clean Agent Extinguishing Systems
NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems
NBC 2016 – Fire protection for special occupancies
Benefits –
Environmentally sustainable
Non-conductive and residue-free
Safe for occupied areas
Quick activation within seconds
Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Still searching for heat balancing and trap survey services?
Gat No. 447, Maitri Park, Plot No. E20, E30, Khadi Machine Road, Moshi, Pimpri-Chinchwad,