Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042755939 (International callers) or 08042755939 (Indian callers).
*Description*: Complete SWV systems from fixture traps to soil/waste stacks, vents, and external collection lines up to the manhole/sewer or STP. We ensure gradients, venting, and cleanouts are correct so blockages and odors are minimized. External networks are laid with proper bedding, levels, and access chambers for easy maintenance.
Compliances: NBC 2016 plumbing provisions; local authority sewer connection norms; good engineering practices for traps/vents/gradients.
Benefits: Fewer blockages, no odor complaints, long service life, easy maintenance with planned cleanouts and chambers.
Why Choose Us: Thoughtful routing that respects architecture/MEP clashes, neat shaft detailing, and handover with line-by-line test records.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description:
Preventive and breakdown maintenance to keep fire systems inspection‑ready. Includes routine checks, emergency callouts, spares planning, and statutory documentation support.
Compliances:
OEM/IS/NFPA maintenance recommendations; local authority readiness for audits.
Benefits:
Higher system reliability, faster fault response, extended equipment life, and smoother inspections/NOCs.
Why Choose Us:
Structured checklists, SLA‑based response, trained technicians, and digital service reports with photo logs.
Description: Site-wide storm water systems handling peak monsoon flows via catch pits, gratings, roadside drains, and underground pipes to outfalls/recharge structures. We design gradients and capacities to prevent flooding, waterlogging, and damage to roads, basements, or landscaping.
Compliances: Local municipal storm-water norms; NBC/CPHEEO guidance for drainage design.
Benefits: Flood-safe site, longer pavement life, clean landscaped areas, reduced complaints and downtime.
Why Choose Us: Accurate hydraulic calculations, proper silt control, accessible chambers, and as-built levels that actually match site contours.
Description:
Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection.
Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment.
Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels.
Compliance –
IS 15493 – Clean Agent Extinguishing Systems
NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems
NBC 2016 – Fire protection for special occupancies
Benefits –
Environmentally sustainable
Non-conductive and residue-free
Safe for occupied areas
Quick activation within seconds
Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.
Description:
Early detection of water leaks in data centers, server rooms, UPS rooms, laboratories, archives and false floors using spot sensors or addressable leak‑detection cables. The system pinpoints location, triggers local/buzzer alarms, and can notify BMS to shut down sensitive equipment or close motorized valves.
Compliances:
Best practices for mission‑critical facilities; OEM sensor/controller guidelines; integration per BMS protocols.
Benefits:
Prevents damage to electrical/electronics, reduces downtime, and protects high‑value rooms and records.
Why Choose Us:
Clean cable routing, address mapping, supervised loops, and tested alarms with clear as‑builts and maintenance SOPs.
Description:
High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones.
Compliances:
ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards.
Benefits:
Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning.
Why Choose Us:
Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.
Description:
Code‑compliant ventilation and exhaust for basements, kitchens, toilets and process areas. We size fans/ducts, ensure correct air changes, smoke extraction logic where required, and deliver low‑loss layouts with access for maintenance.
Compliances:
NBC ventilation & smoke control provisions, IS/ASHRAE guidance, local fire approvals where applicable.
Benefits:
Better IAQ, controlled odors/fumes, safer egress during smoke events, and lower fan power.
Why Choose Us:
Balanced, maintainable routing with sound attenuation, tested airflow, and clear as‑builts.