Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042755939 (International callers) or 08042755939 (Indian callers).
Description:
High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones.
Compliances:
ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards.
Benefits:
Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning.
Why Choose Us:
Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.
The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies.
Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system.
Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings.
Compliance –
IS 15301 – Fire Pump Installation
NFPA 20 – Installation of Fire Pumps
NBC 2016 – Fire water supply requirements
Benefits –
Continuous water availability
Fully automated with control panel
Integrated monitoring for reliability
Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.
Description:
Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor.
Compliances:
- NBC 2016 – Part 4 (Fire & Life Safety)
- IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets
- IS 2189 / NFPA 72 for fire detection & alarm (when in scope)
- NFPA 20 / NFPA 13 / NFPA 2001 (as applicable)
- Local CFO / Fire Brigade requirements for provisional and final NOC
Benefits:
- One-point accountability – no multi-vendor disputes
- Faster fire NOC because drawings, test certificates and demonstrations are handled together
- Standardised and approved make materials → better reliability
- Installation with testing (hydro, flushing, pump trials) and complete O&M handover
- Option to continue with AMC from the same team
Why Choose Us:
- Govt-approved / class-A fire & safety contractor with multi-sector experience
- Fire projects executed in industrial, healthcare, warehousing and commercial facilities
- We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority
- We train your operators on hydrant/sprinkler/pump panel so the system is actually usable
- Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description: STPs treat domestic wastewater from residential, commercial, healthcare, and IT parks to meet discharge/reuse norms. We design compact, odor-controlled plants using MBBR/SBR/MBR to achieve consistent BOD, COD, and TSS reduction. Treated water can be reused for flushing, landscaping, or HVAC make-up, cutting freshwater bills and improving sustainability scores.
Compliances: CPCB / Local Urban Body standards; NBC guidance for plumbing and reuse.
Benefits: Lower freshwater dependency, stable effluent quality, small footprint options, easy operation, and potential green building credits.
Why Choose Us: Complete civil + electro-mechanical delivery, automation with alarms, trial run & stabilization, operator training, and reuse integration (tanks/boosters).
Description:
Our Clean Agent Fire Suppression System provides rapid fire protection for sensitive environments without leaving any residue. Designed as per IS 15493, NFPA 2001, and NBC 2016, this system uses agents like HFC-227ea (FM-200) or FK-5-1-12 (Novec 1230) for total flooding protection.
Introduction – A Clean Agent System extinguishes fire by heat absorption and chemical reaction interruption while being safe for people and equipment.
Applications – Data centers, control rooms, archives, server racks, telecom rooms, laboratories, and switchgear panels.
Compliance –
IS 15493 – Clean Agent Extinguishing Systems
NFPA 2001 – Standard on Clean Agent Fire Extinguishing Systems
NBC 2016 – Fire protection for special occupancies
Benefits –
Environmentally sustainable
Non-conductive and residue-free
Safe for occupied areas
Quick activation within seconds
Why Choose Us – We provide design, supply, installation, commissioning, and AMC for clean agent systems, ensuring full compliance with government fire authorities and easy NOC approval.
Description:
Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements.
Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels.
Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks.
Compliance –
IS 2189 – Fire Detection & Alarm Systems
NFPA 72 – National Fire Alarm & Signaling Code
NBC 2016 – Fire detection provisions for various occupancies
Benefits –
Early warning saves lives
Automatic alarms with integration to suppression systems
Compatible with NOC approval requirements
Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.
Still searching for commercial and industrial hvac duct installation?
Gat No. 447, Maitri Park, Plot No. E20, E30, Khadi Machine Road, Moshi, Pimpri-Chinchwad,