Fire Protection Systems

Description: Our Fire Detection & Alarm System ensures early detection of fire and immediate notification for safe evacuation. Compliant with IS 2189, NFPA 72, and NBC 2016, we provide both conventional and addressable systems tailored to site requirements. Introduction – Detection systems include smoke detectors, heat detectors, flame detectors, and manual call points connected to fire alarm panels. Applications – Offices, hotels, malls, residential towers, hospitals, industrial plants, warehouses, IT parks. Compliance – IS 2189 – Fire Detection & Alarm Systems NFPA 72 – National Fire Alarm & Signaling Code NBC 2016 – Fire detection provisions for various occupancies Benefits – Early warning saves lives Automatic alarms with integration to suppression systems Compatible with NOC approval requirements Why Choose Us – We supply, install, test, and maintain complete fire detection solutions including wiring, panels, detectors, sounders, and networking.

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Early warning and guided evacuation using addressable fire detection integrated with public address/voice evacuation (PA/VA). We program cause‑&‑effect for alarm stages, AHU/lift/damper interlocks, and phased voice messages so people exit quickly and safely without panic. Compliances: IS 2189 (Fire detection & alarm), NFPA 72 (Signaling), NBC 2016 (Evacuation), OEM standards for PA/VA. Benefits: Faster detection & response, clear voice guidance, reduced evacuation time, smoother fire NOC approval. Why Choose Us: End‑to‑end delivery — survey, loop design, cabling, device programming, voice logic, integrated testing with documentation your authority expects.

Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

Card 2

product image
Fire Protection Systems

Description: A compact, fully autonomous suppression solution, our Tube-Based Fire Suppression System detects and extinguishes fires directly at the source. Compliant with IS 15302 and NFPA 2001, this system is ideal for electrical panels, CNC machines, engine bays, and confined enclosures. Features: 1.Flexible detection tube ruptures at heat source 2.Direct discharge onto fire 3.No external power supply needed Benefits: 1.Quick localized suppression 2.Minimal collateral damage 3.Easy installation in compact spaces Key Property: Activation Method – Heat Sensitive Tube Other Specifications: 1.Standard: IS 15302 / NFPA 2001 2.Agent Type: Clean agent / CO₂ 3.Operating Pressure: 10–20 bar 4.Tube Material: Nylon/polyamide high-temp resistant

Card 2

product image
Fire Protection Systems

Description: Our Kitchen Fire Suppression System is specially designed to combat high-temperature cooking oil and grease fires. Built to UL 300 and NFPA 17A standards, it provides automatic detection and wet chemical discharge to suppress flames and cool surfaces. Applications: Hotels, restaurants, commercial kitchens, food processing plants. Benefits: 1. Prevents re-ignition 2. Fast, automatic activation 3. Safe for food environments 4. Key Property: Agent Type – Wet Chemical Other Specifications: 1. Standard: UL 300 / NFPA 17A 2. Discharge Time: < 10 seconds 3. Coverage: Based on hood size 4. Cylinder Material: Carbon steel, epoxy coated

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Clear public announcements for plants, malls, campuses and offices using zonal or networked PA. Designed for audibility and intelligibility with microphones, paging stations, amplifiers and ceiling/column speakers. Compliances: IS/NBC audibility guidance; OEM standards for SPL and THD. Benefits: Improved communication, emergency paging, scheduled messages, and integration with fire alarm if needed. Why Choose Us: Coverage mapping, correct wattage tapping, neat rack build, and user training for paging routines.

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Early detection of water leaks in data centers, server rooms, UPS rooms, laboratories, archives and false floors using spot sensors or addressable leak‑detection cables. The system pinpoints location, triggers local/buzzer alarms, and can notify BMS to shut down sensitive equipment or close motorized valves. Compliances: Best practices for mission‑critical facilities; OEM sensor/controller guidelines; integration per BMS protocols. Benefits: Prevents damage to electrical/electronics, reduces downtime, and protects high‑value rooms and records. Why Choose Us: Clean cable routing, address mapping, supervised loops, and tested alarms with clear as‑builts and maintenance SOPs.

Card 2

product image
Industrial Utilities & Process Control Systems

Description: Design and installation of safe, code-compliant fuel oil storage and transfer systems for boilers, furnaces, and DG sets. Includes tanks, day tanks, pumps, strainers, heating (if required), level instrumentation, leak detection and interlocks. Compliances: PESO/CCOE norms for storage & handling; IS fire safety practices; electrical hazardous area classification where applicable. Benefits: Reliable supply, spill/leak minimization, improved burner performance, safer operation. Why Choose Us: Right materials & heat tracing, double-walled lines (as needed), tidy routing, alarms, and tested logic for start/stop and high/low levels.