Mumbai
08042756194
+918956051383

'high pressure firefighting water supply system'

Items tagged with 'high pressure firefighting water supply system'

Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

Card 2

product image
Fire Protection Systems

Description: A compact, fully autonomous suppression solution, our Tube-Based Fire Suppression System detects and extinguishes fires directly at the source. Compliant with IS 15302 and NFPA 2001, this system is ideal for electrical panels, CNC machines, engine bays, and confined enclosures. Features: 1.Flexible detection tube ruptures at heat source 2.Direct discharge onto fire 3.No external power supply needed Benefits: 1.Quick localized suppression 2.Minimal collateral damage 3.Easy installation in compact spaces Key Property: Activation Method – Heat Sensitive Tube Other Specifications: 1.Standard: IS 15302 / NFPA 2001 2.Agent Type: Clean agent / CO₂ 3.Operating Pressure: 10–20 bar 4.Tube Material: Nylon/polyamide high-temp resistant

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Early detection of water leaks in data centers, server rooms, UPS rooms, laboratories, archives and false floors using spot sensors or addressable leak‑detection cables. The system pinpoints location, triggers local/buzzer alarms, and can notify BMS to shut down sensitive equipment or close motorized valves. Compliances: Best practices for mission‑critical facilities; OEM sensor/controller guidelines; integration per BMS protocols. Benefits: Prevents damage to electrical/electronics, reduces downtime, and protects high‑value rooms and records. Why Choose Us: Clean cable routing, address mapping, supervised loops, and tested alarms with clear as‑builts and maintenance SOPs.

Card 2

product image
Plumbing & Drainage Systems

Description: End-to-end design and execution of building/industrial water networks—from source tapping and treatment interface to storage, boosting, and floor-wise distribution. We engineer pipes, valves, NRVs, PRVs and meters so every outlet gets the right pressure/flow without noise, hammer, or dead legs. Suitable for residential towers, IT parks, malls, hospitals, and plants. Compliances: NBC 2016 guidance for plumbing; CPHEEO Manual practices; IS pipe/material standards as specified by client/authority. Benefits: Assured pressure at fixtures, reduced leakage and water hammer, hygienic layouts, simplified maintenance, and lower lifecycle costs. Why Choose Us: Practical hydraulics, accurate sizing, clean riser/shaft detailing, and commissioning with pressure/flow records—plus clear as-builts and O&M for facility teams.

Card 2

product image
Plumbing & Drainage Systems

Description: Capture and utilize roof/terrace runoff through down-take pipes, filters, silt traps, storage, and recharge pits/bores or reuse loops. We size components based on rainfall intensity and roof area so your system actually works during monsoons and reduces dependency on tankers/municipal supply. Compliances: Local development authority RWH by-laws; NBC guidance on water conservation; CPHEEO practices. Benefits: Lower freshwater bills, improved groundwater recharge, ESG/green points, reduced storm drain burden. Why Choose Us: Correct hydraulic sizing, debris/silt control, safe overflow paths, and easy-to-maintain filter layouts with documented O&M.

Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

Card 2

product image
Fire Protection Systems

Description: Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses. Key Components: Sprinkler heads (pendent, upright, sidewall) Distribution piping & alarm valves Water supply pumps & tanks Flow switches & monitoring systems Compliance: IS 15105 – Design & installation requirements for sprinkler systems NFPA 13 – Standard for installation of sprinkler systems NBC 2016 – Fire zone & occupancy-specific guidelines Why Choose Us: We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform. Benefits: Quick suppression at fire origin Reduces smoke & property damage Automatic activation without human intervention

Card 2

product image
Fire Protection Systems

Description: Our CO₂ Gas Fire Suppression System provides high-efficiency fire suppression using carbon dioxide, ideal for unoccupied areas where water or clean agents are not suitable. Designed as per IS 6382, NFPA 12, and NBC 2016, this system ensures rapid discharge and total flooding capability. Introduction – CO₂ suppresses fire by oxygen displacement and cooling effect, making it perfect for high-risk industrial applications. Applications – Power plants, generator rooms, turbine enclosures, paint booths, foundries, industrial machinery, cable tunnels. Compliance – IS 6382 – CO₂ Fire Extinguishing Systems NFPA 12 – Carbon Dioxide Extinguishing Systems NBC 2016 – Provisions for gaseous suppression Benefits – Rapid fire knockdown No water damage to equipment Cost-effective suppression solution Why Choose Us – We provide turnkey solutions from design to commissioning, including safety interlocks, alarms, and AMC services.

Still searching for
high pressure firefighting water supply system?