Hyderabad
08042754670
+918956051383

'vfds for chillers pumps fans'

Items tagged with 'vfds for chillers pumps fans'

Card 2

product image
Energy Management & Audit Services

Description: Performance evaluation of chillers, cooling towers, pumps, AHUs, VRF/VRV and ventilation to reduce kW/TR and improve comfort. We optimize water/air balances, reset strategies, schedules, filters, heat-recovery options, and propose VFDs and control logic to cut energy while maintaining IAQ. Compliances: ASHRAE benchmarking (reference), IS HVAC practices, IAQ guidance for ventilation. Benefits: Lower kWh, improved comfort, extended equipment life, better maintenance planning, reduced complaints. Why Choose Us: Hands-on balancing, realistic set-points, no fancy jargon—just actionable changes with measured before/after TR, ΔT and kW/TR.

Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

Card 2

product image
Water & Wastewater Treatment Systems (WTP/ETP/STP)

Description: RO systems reduce TDS and specific ions to deliver consistent process or utility water for beverages, electronics, pharma pre-treatment, and boiler make-up. We engineer the right pretreatment (PSF/ACF/UF), antiscalant dosing, and CIP strategy to protect membranes and maximize recovery—cutting water and energy costs. Skid-mounted designs fit existing plants without civil rework, and controls provide real-time quality monitoring. Compliances: Meets process specifications and membrane OEM guidelines; references IS 10500 for potable usage targets when required. Benefits: Predictable low-TDS water, longer membrane life, lower scaling/fouling risk, modular capacity upgrades, and lower overall OPEX. Why Choose Us: Feed characterization, membrane selection, energy-efficient pumps/VFDs, PLC/SCADA with alarm logging, and CIP provisions ensure dependable, serviceable systems.

Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

Card 2

product image
Fire Protection Systems

Description: Our Fire Sprinkler Systems are designed for automatic fire suppression, ensuring localized and immediate control over fire outbreaks. Compliant with IS 15105, NFPA 13, and NBC 2016, these systems are suitable for offices, malls, factories, and warehouses. Key Components: Sprinkler heads (pendent, upright, sidewall) Distribution piping & alarm valves Water supply pumps & tanks Flow switches & monitoring systems Compliance: IS 15105 – Design & installation requirements for sprinkler systems NFPA 13 – Standard for installation of sprinkler systems NBC 2016 – Fire zone & occupancy-specific guidelines Why Choose Us: We carry out hazard classification, hydraulic calculations, and layout optimization to deliver maximum protection with minimum downtime. Our AMC services ensure your system is always ready to perform. Benefits: Quick suppression at fire origin Reduces smoke & property damage Automatic activation without human intervention

Card 2

product image
Fire Protection Systems

The Fire Pump Room System is the backbone of every firefighting installation, ensuring reliable water supply at adequate pressure to hydrants, sprinklers, and spray systems. Designed in compliance with IS 15301, NFPA 20, and NBC 2016, our pump room setups guarantee performance during emergencies. Introduction – The pump room houses main pumps, jockey pumps, diesel engines, electrical controls, and valves, forming the heart of the fire water supply system. Applications – Industrial plants, commercial complexes, IT parks, refineries, warehouses, hospitals, and high-rise buildings. Compliance – IS 15301 – Fire Pump Installation NFPA 20 – Installation of Fire Pumps NBC 2016 – Fire water supply requirements Benefits – Continuous water availability Fully automated with control panel Integrated monitoring for reliability Why Choose Us – We deliver complete turnkey fire pump room solutions including design, supply, installation, electrical wiring, hydro testing, and AMC.

Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: High‑efficiency centralized cooling for commercial, industrial and healthcare facilities using water‑cooled/air‑cooled chillers or VRF‑VRV systems. We size loads, perform pipe/duct routing, balance flows, and optimize controls to achieve target kW/TR and comfort across zones. Compliances: ASHRAE fundamentals (reference), IS HVAC practices, local ventilation & IAQ guidelines, OEM installation standards. Benefits: Lower energy use, stable comfort, quieter operation, and scalable capacity with zoning. Why Choose Us: Hands‑on balancing, neat detailing, vendor‑neutral design, and commissioning with measured TR, ΔT and kW/TR.

Card 2

product image
Heating, Ventilation & Air Conditioning (HVAC) Systems

Description: Code‑compliant ventilation and exhaust for basements, kitchens, toilets and process areas. We size fans/ducts, ensure correct air changes, smoke extraction logic where required, and deliver low‑loss layouts with access for maintenance. Compliances: NBC ventilation & smoke control provisions, IS/ASHRAE guidance, local fire approvals where applicable. Benefits: Better IAQ, controlled odors/fumes, safer egress during smoke events, and lower fan power. Why Choose Us: Balanced, maintainable routing with sound attenuation, tested airflow, and clear as‑builts.

Still searching for
vfds for chillers pumps fans?