Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108042754670 (International callers) or 08042754670 (Indian callers).
Description:
Safe earthing networks and lightning protection designed per soil resistivity and building profile. We deliver earth grids, pits, bonding, SPD selection, and air‑termination/down‑conductors sized to handle faults and surges—protecting people, equipment, and data.
Compliances:
IS/IEC earthing & lightning standards; risk assessment per IEC 62305 where applicable.
Benefits:
Lower touch/step voltages, improved equipment safety, fewer nuisance trips, and better surge immunity.
Why Choose Us:
Measured soil tests, engineered layouts, resistance targets with test logs, and maintainable inspection chambers.
Description:
End‑to‑end integration of solar PV into your LV/MV network—right‑sized arrays, string/inverter selection, protections, earthing/SPDs, and metering aligned to your load profile. We handle structure checks, SLDs, CEIG/DISCOM documentation, and safe interlocking with DG sets for reliability.
Compliances:
DISCOM/CEIG approvals, IEC/IS standards for PV modules/inverters/protection, net‑metering/open‑access rules as applicable.
Benefits:
Lower grid kWh and demand charges, tariff hedging, improved ESG profile, and long‑life, low‑maintenance generation.
Why Choose Us:
Bankable engineering with shading analysis, PR estimates, surge/lightning protection, robust earthing, and clear economics (CAPEX/OPEX/RESCO) with post‑commissioning performance tracking.
Description:
Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team.
Mechanical (M) Scope:
- HVAC: chiller / VRF-VRV / ventilation / pressurization
- Utility piping where applicable
- Equipment installation: AHUs, pumps, fans, cooling towers
Electrical (E) Scope:
- HT/LT panels, PCC/MCC/APFC, cabling & terminations
- Earthing & lightning protection
- DG/UPS/LV/ELV integration
- Lighting & small power for building/common areas
Plumbing (P) Scope:
- Water supply & internal plumbing
- Drainage, rainwater, harvesting connections
- Domestic and firefighting pump rooms (segregated)
Fire (F) Scope:
- Hydrant, sprinkler, detection, gas suppression
- Pump room and NOC documentation
Compliances:
- NBC 2016 – building services & fire
- IS / ASHRAE good practices for HVAC
- IS / IEC for electrical & earthing
- Local plumbing/water supply bye-laws
- DISCOM / CEIG / Fire Brigade requirements
Benefits:
- One vendor → one timeline → one handover
- Common supports/trenches/shafts → cost optimisation
- Faster authority approvals because documents come from one source
- Easier for facility/maintenance teams to run systems post-handover
Why Choose Us:
- We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless
- Experienced in factories, commercial, IT/office, hospitals, warehouses
- Strong site management with DPRs, QAP, test reports and stage-wise billing
- Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar
Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations.
Key Components:
Hydrant valves (landing valves)
Hose reels & hoses
Fire pumps & jockey pumps
Underground/aboveground piping network
Yard hydrants & breeching inlets
Compliance & Standards:
IS 13039 – Requirements for installation and maintenance of hydrant systems
NFPA 24 – Private fire service mains & hydrants
NBC 2016 – Layout, spacing & water storage norms for hydrants
Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities.
Why Choose Us:
We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals.
Benefits:
Rapid water availability during emergencies
Durable materials for long service life
Easy maintenance & accessibility
Fully compliant with statutory fire safety codes
Description:
High‑resolution IP CCTV with NVR/VMS for perimeter, production floors, warehouses, parking and public areas. We design camera placement, lens/fov, lighting and network to capture the right angles in the right detail — and retain footage compliantly.
Compliances:
IT/security best practices; data retention policies; PoE/PoE+ standards; surge/earthing norms.
Benefits:
Better incident evidence, fewer blind spots, remote monitoring, and scalable storage.
Why Choose Us:
Camera plan with height/fov, structured cabling, switches, racks, UPS, and commissioning with VMS user training.
Description:
Our Turnkey Fire Fighting Solutions are for industries, commercial buildings, hospitals, IT parks, warehouses, logistics hubs, and high-rise projects that want a single agency to handle the complete fire package. We take responsibility from concept and authority-compliant design to supply of approved materials, execution at site, testing/commissioning, fire department demonstration and final NOC. Systems are engineered as per NBC 2016, IS standards and NFPA references and can include hydrant, sprinkler, detection, gas suppression, pump room and passive fire protection as per project needs. This removes the headache of coordinating between designer, material vendor and installation contractor.
Compliances:
- NBC 2016 – Part 4 (Fire & Life Safety)
- IS 13039 / IS 15105 / IS 15301 for hydrant, sprinkler and pump sets
- IS 2189 / NFPA 72 for fire detection & alarm (when in scope)
- NFPA 20 / NFPA 13 / NFPA 2001 (as applicable)
- Local CFO / Fire Brigade requirements for provisional and final NOC
Benefits:
- One-point accountability – no multi-vendor disputes
- Faster fire NOC because drawings, test certificates and demonstrations are handled together
- Standardised and approved make materials → better reliability
- Installation with testing (hydro, flushing, pump trials) and complete O&M handover
- Option to continue with AMC from the same team
Why Choose Us:
- Govt-approved / class-A fire & safety contractor with multi-sector experience
- Fire projects executed in industrial, healthcare, warehousing and commercial facilities
- We prepare BOQ, GFC/shop drawings, test reports and as-built documents for authority
- We train your operators on hydrant/sprinkler/pump panel so the system is actually usable
- Local execution/support teams in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar, and Pan India
Description:
Structured LAN & fiber networks for offices, plants and campuses. We plan IDFs/MDFs, pathways, racks, cable management, labeling and testing so the network is fast, reliable and easy to maintain.
Compliances:
TIA/EIA cabling standards; PoE/PoE+; earthing & surge norms for outdoor links.
Benefits:
Higher uptime, easier troubleshooting, scalable backbone, PoE readiness for cameras/Wi‑Fi/phones.
Why Choose Us:
Certified terminations, test reports, rack build discipline, and clear as‑built documentation.