Hyderabad
08042754670
+918956051383

'card and pin door access management'

Items tagged with 'card and pin door access management'

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Role‑based access to doors, labs, server rooms and turnstiles with card/PIN/biometric/mobile credentials. We structure controllers, readers, locks, and door hardware so security is strong but day‑to‑day movement stays smooth. Compliances: Electrical & fire egress norms; data security best practices; ADA/accessibility guidance as applicable. Benefits: Audit trails, time‑based permissions, anti‑passback, and easier visitor management. Why Choose Us: Neat door schedules, wiring, fail‑safe/secure logic, and integration with HR/MS/attendance if required.

Card 2

product image
Fire Protection Systems

Description: Limit smoke and flame spread with rated fire doors, fire curtains and certified fire‑stopping for cable/pipe penetrations. Proper compartmentation buys evacuation time and protects escape routes and assets. Compliances: NBC 2016 passive fire provisions; manufacturer test certificates/UL/BS/IS as applicable. Benefits: Better life safety, smaller fire/smoke spread, improved NOC/insurance compliance, cleaner post‑incident restoration. Why Choose Us: Detailing that matches approvals, correct materials (intumescent sealants, collars, wraps), site inspections and closure documentation. Other specifications:

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Automated entry/exit management with boom barriers, sliding/swing gates, tyre killers and bollards integrated to RFID/ANPR or access control. Built for continuous duty cycles and outdoor reliability. Compliances: Electrical safety for outdoor equipment; traffic/road safety norms. Benefits: Faster gate operations, better security logs, reduced manpower dependency. Why Choose Us: Mechanical + electrical integration expertise, civil foundations, wiring, and maintenance planning for high‑throughput sites.

Card 2

product image
Turnkey Solutions

Description: Our Turnkey MEP Solutions are built for clients who want a single partner for all building services instead of coordinating 4–5 separate agencies. We take over the complete MEP-F scope – design coordination with architect/PMC, BOQ finalization, supply of approved makes, site execution, testing/commissioning and authority clearances (fire, water, DISCOM/CEIG as applicable). The result is a clash-free, inspection-ready, cost-optimised services package delivered by one accountable team. Mechanical (M) Scope: - HVAC: chiller / VRF-VRV / ventilation / pressurization - Utility piping where applicable - Equipment installation: AHUs, pumps, fans, cooling towers Electrical (E) Scope: - HT/LT panels, PCC/MCC/APFC, cabling & terminations - Earthing & lightning protection - DG/UPS/LV/ELV integration - Lighting & small power for building/common areas Plumbing (P) Scope: - Water supply & internal plumbing - Drainage, rainwater, harvesting connections - Domestic and firefighting pump rooms (segregated) Fire (F) Scope: - Hydrant, sprinkler, detection, gas suppression - Pump room and NOC documentation Compliances: - NBC 2016 – building services & fire - IS / ASHRAE good practices for HVAC - IS / IEC for electrical & earthing - Local plumbing/water supply bye-laws - DISCOM / CEIG / Fire Brigade requirements Benefits: - One vendor → one timeline → one handover - Common supports/trenches/shafts → cost optimisation - Faster authority approvals because documents come from one source - Easier for facility/maintenance teams to run systems post-handover Why Choose Us: - We already execute fire + LV + utilities → adding HVAC, electrical & plumbing is seamless - Experienced in factories, commercial, IT/office, hospitals, warehouses - Strong site management with DPRs, QAP, test reports and stage-wise billing - Local presence in Pune, Mumbai, Bengaluru, Hyderabad, Chhatrapati Sambhajinagar

Card 2

product image
Fire Protection Systems

Our Fire Hydrant System is a robust firefighting solution engineered to provide high-pressure water flow for emergency use in industrial, commercial, and residential premises. Designed and installed in compliance with IS 13039, NFPA 24, and NBC 2016 Part 4, this system ensures an uninterrupted water supply and pressure for firefighting operations. Key Components: Hydrant valves (landing valves) Hose reels & hoses Fire pumps & jockey pumps Underground/aboveground piping network Yard hydrants & breeching inlets Compliance & Standards: IS 13039 – Requirements for installation and maintenance of hydrant systems NFPA 24 – Private fire service mains & hydrants NBC 2016 – Layout, spacing & water storage norms for hydrants Applications: Factories, warehouses, high-rise buildings, hospitals, educational institutes, and large public facilities. Why Choose Us: We provide end-to-end service — site survey, hydraulic calculations, system design, supply, installation, commissioning, and annual maintenance contracts (AMC). All installations meet local fire department and authority guidelines, ensuring quick NOC approvals. Benefits: Rapid water availability during emergencies Durable materials for long service life Easy maintenance & accessibility Fully compliant with statutory fire safety codes

Card 2

product image
Low Voltage & Electronic Security Systems

Description: Structured LAN & fiber networks for offices, plants and campuses. We plan IDFs/MDFs, pathways, racks, cable management, labeling and testing so the network is fast, reliable and easy to maintain. Compliances: TIA/EIA cabling standards; PoE/PoE+; earthing & surge norms for outdoor links. Benefits: Higher uptime, easier troubleshooting, scalable backbone, PoE readiness for cameras/Wi‑Fi/phones. Why Choose Us: Certified terminations, test reports, rack build discipline, and clear as‑built documentation.

Card 2

product image
Industrial Utilities & Process Control Systems

Description: End-to-end compressed air solutions including compressors, dryers, receivers, filters, and ring mains. We size capacity/pressure, leakage index, dew-point targets, and deliver clean, dry air to machines while reducing energy use and downtime. Compliances: OEM guidelines for air quality classes (ISO 8573), safety valves & piping practices; IS standards for pressure vessels where applicable. Benefits: Lower energy per m³, fewer breakdowns, longer tool life, and stable pressure across shifts. Why Choose Us: Data-led sizing, leakage audits, heat recovery options, condensate management, and P&IDs with clear O&M.

Card 2

product image
Industrial Utilities & Process Control Systems

Description: Process cooling networks designed for flow balance, NPSH, and temperature control—covering cooling towers, pumps, exchangers, and distribution. We minimize pumping power, ensure correct velocities, and plan chemical treatment points. Compliances: IS/ASHRAE guidance for cooling water; OEM guidelines for exchangers/pumps; water chemistry best practices. Benefits: Lower energy per m³, stable process temperatures, reduced fouling/scaling, and longer equipment life. Why Choose Us: Hydraulic modeling, debris management, treatment dosing, and well-documented O&M with KPIs for ΔT, approach, and cycles of concentration.

Card 2

product image
Industrial Utilities & Process Control Systems

Description: Plant‑wide utility piping with correct pipe schedules, slopes, supports, and expansion allowances. We route for safety and maintainability, avoid dead‑legs, and provide drain/vent points for safe commissioning and upkeep. Compliances: IS/ASME B31 piping practices; insulation & heat tracing codes; color coding & identification standards. Benefits: Lower leaks, easier maintenance, safer operations, and predictable pressure/temperature performance. Why Choose Us: Practical detailing, spool drawings, isometrics with BOM, weld maps, and weld/NDT records for traceability.

Still searching for
card and pin door access management?